Solarwinds wmi polling requirements. I can add some but I cant add others.

Solarwinds wmi polling requirements. AppInsight for IIS data is collected at the same default 5-minute polling interval as other application templates. Scalability engines include Additional polling engines (APEs), Additional web server (AWS), and high availability (HA) backup servers. SAM 2020. This topic describes how you can change the method for polling a device monitored with your SolarWinds Platform product. Enable the Inbound Rules in the WMI group and create firewall exceptions to allow You can use SolarWinds SAM to monitor hardware health for Dell, HP, HPE Proliant, and IBM devices. Support the use of a lesser priviledged WMI account; and b. solarwinds. The ports vary between products and some are configurable. SolarWinds recommends using a dedicated Windows account with low-level privileges for PowerShell monitors, especially for scripts executed on polling engines that use the same Windows account as the SolarWinds Platform server. This is the same as when the data is polled agentlessly, because in most cases, Agents use the same methods for collecting data as agentless polling. Learn about agent vs. Apr 1, 2019 · Due to security requirements, I'm attempting to configure a SolarWinds domain service account that does not need administrative rights on each machine, and I'd like This topic describes requirements and permissions for configuring AppInsight for IIS nodes in your environment. The polling engine requests real-time statistics (through the selected polling method, such as SNMP or WMI) from monitored devices in your environment. See full list on documentation. agentless polling. It includes the port numbers, descriptions of their uses, and in some cases which components or products they are used with. Our systems team uses KACE to push the agent and they have incorporated the installer into new server builds so it gets deployed when new hosts are spun up. These can be set up and edited on the Manage Active Directory Administrator Credentials page, or created when you add a controller. Find out how to configure Kerberos for WMI authentication for SolarWinds Platform products. Configure SNMP for SolarWinds Platform agents on Linux/Unix and AIX systems in SAM SolarWinds Platform agents provide a secure, encrypted communication channel between the SolarWinds Platform server and Windows, Linux/Unix, or AIX systems, as an alternative to WMI or SNMP to gather data about key servers, processes, and applications in your environment. It lists the port requirements for what you are asking for under NPM and SAM Active Directory credentials are required for the Active Directory domain controllers you add to UDT. This topic also describes how to check your license type and manage licenses, plus how SAM licensing works in conjunction with Network Performance Monitor (NPM), Network Automation Manager (NAM), Log Analyzer (LA), and Server Configuration Monitor (SCM in regard to Additional Polling Engines (APEs). Then re-adding the node resolved the CPU issue. What are the… May 9, 2008 · WMI is dynamic ports it can use any ports best thing to do is either do the fixed port listed above, do source and destination rule or you can also use the Solarwinds Agent which only uses port 17777 and port 17778. We use Solarwinds for our network and server monitoring. It seems like there is a port not defined in the "Server & Application Monitor WMI Requirements" section. To learn about best practices for configuring your SolarWinds Platform installation securely, see Secure Configuration for the SolarWinds Platform. 1, as a single product installed on SolarWinds Platform 2024. I downloaded WMIdiag diagnostic tool from Microsoft, I ran this tool on the server which I added to solarwinds and also ran it in the server which is refusing wmi (test failed). Do not run untested PowerShell scripts against a production instance of the SolarWinds Platform. Refer to your product Administrator Guide for more information. May 12, 2020 · Hello Solarwinds - Does a document exist on what ports need to be open on a Server 2019 firewall to allow WMI to communicate? I have been searching and have not found anything that mentions this. WMI agentless polling. For Agent nodes, polling runs without any specific credentials using the Local System account under which the agent service runs on the target node. What should I check? Logs that might show what is going… Feb 6, 2024 · These recommended system requirements are for SolarWindsWeb Performance Monitor (WPM) 2024. How AppInsight collects Active Directory data In the AppInsight for Active Directory template, WinRM is the default transport method used to fetch data for WMI-based component monitors. Some component monitors do not support polling via SolarWinds Platform Remote Collectors (ORCs). On a target server, monitoring with WMI plus a SAM template has no effect whatsoever on RAM or CPU, compared to simple ping monitoring. Feb 6, 2024 · SolarWinds Platform SQL database requirements The following table lists software and hardware requirements for your SolarWinds Platform database server. SAM automatically switches to DCOM as a fallback method to collect data if WinRM fails during a polling cycle, and then works through other methods until polling succeeds. Use gMSA credentials in the format <username>$@<domain> or <domain>\<username>$ The domain name must be in the FQDN format. WinRM is the default fetching method for WMI-based component monitors. WinRM fallback can negatively impact polling times. Oct 27, 2021 · We’re currently in process of securing our environment. This article allows you to see information from Microsoft on setting up a fixed port for WMI. Nov 4, 2013 · Note: Due to specific characteristics of WMI polling requests, polling a single WMI enabled object uses approximately five times the resources required to poll the same or similar object with SNMP on the same polling frequency. For previous versions, see Use WinRM for application monitor polling in SAM. Reorder credentials: The order of polling methods is set by the preferred method selection. By using scheduled WMI discovery, Web Help Desk can periodically poll endpoints to update hardware and software inventory information. . Scalability Engine Requirements Scalability engine requirements are generally the same as the requirements for a primary polling engine. Network admin reference. Windows Service Monitors are SAM component monitors that track statistics for Windows services and applications. For best results, SolarWinds recommends always using the VMAN Orion polling method, which collects extensive data and metrics for virtual systems including clusters, hosts, datastores, and virtual machines. Mar 25, 2014 · The last I heard in April was this section of the Port Requirements document was due to be updated, with the Additional Web Server requirements to be updated shortly after. If you need to close ports 22, contact Oct 18, 2018 · Learn how to test WMI connectivity using WBEMTest in the Orion Platform for troubleshooting and ensuring smooth operation of your network monitoring tools. Feb 15, 2023 · monitored objects that use WMI. The Windows agent is being deployed by a 3rd party Enterprise software application, IBM BigFix. The following instructions apply to SolarWinds Observability Self-Hosted and SolarWinds Platform, including SAM version 2025. WinRM Sep 14, 2023 · Due to specific characteristics of WMI polling requests, polling a single WMI-enabled object uses approximately five times the resources required to poll the same or similar object with SNMP on the same polling frequency. PORT PROTOCOL DIRECTION DESCRIPTION ENCRYPTION 22 TCP bidirectional SSH (secure shell) 23 TCP bidirectional Telnet (non-secure) 53 TCP Used for zone transfers, DNS record polling 135 TCP bidirectional WMI (Windows) 161 UDP Some component monitors have specific port requirements. WMI polling. If you need to disable VBScript, see this article. Learn more about SolarWinds SolarWinds Platform products. What level of access is needed. I can add some but I cant add others. 2. SNMP and WMI polling comparison This article provides details about SNMP vs. 1 instance and am finding that some Windows 2019 servers cannot be polled using the same credential that works in the old instance. For example, you can use them to test if a specified Windows service is running, and then monitor the CPU, virtual memory, and physical memory used by the service. Otherwise, all Windows Script Monitors execute locally on the Main Polling Engine or an APE; an agent allows you to execute scripts on the system where the agent is installed. If you own SAM, and have it deployed on the same system as NPM, you can monitor network interfaces on nodes managed through WMI. Jun 10, 2025 · Using other polling methods (SolarWinds Platform Agent, WMI, or SNMPv3) with authentication or more complex element types (applications, firewalls, load balancers, or wireless controllers) will increase hardware requirements for the server. Additional data is available for nodes managed via WMI. AppInsight for SQL supports SNMP and WMI protocols and uses SQL to gather application data. com A technique for monitoring windows servers via WMI instead of SNMP represents a measurable, but manageable, impact on both the target and the polling engine. Fewer ports: WMI requires several open ports to function properly but SolarWinds Platform agents can use "Server Initiated" mode to operate over a single port. The ports vary from product to product and on a per use basis. For more information, see the installation instructions in the Administrator Guide for your SolarWinds product. Welcome to the SolarWinds Port Requirements reference. Question: Is the "approx 5x resource requirements" on the polling engine or on the end node being polled? Chris. Jan 11, 2021 · Folks, May I know what's if using Solarwinds Orion Polling as opposed to using Agent is faster and lighter ? eg. I resolved the issue by stopping the solarwinds services and restarting the services in the orion service manager. Find out how to scale your deployment with SolarWinds scalability engines. Oct 16, 2024 · Using other polling methods (SolarWinds Platform Agent, WMI, or SNMPv3) with authentication or more complex element types (applications, firewalls, load balancers, or wireless controllers) will increase hardware requirements for the server. SolarWinds Port Requirements The following reference provides a comprehensive list of port requirements for SolarWinds products. Some component monitors have specific port requirements, as detailed in the SAM Application Monitor Template Reference. SolarWinds strongly recommends that you install Web Help Desk on a server that is protected from unauthorized access by the public. This is the port for communication between SolarWinds Servers: WebServer, Additional Polling and HA. This is also used for any API calls; you can use API calls to any SW server. For the latest information, see the Scalability Engine Guidelines, see link below in the Overview. May 17, 2024 · I definitely prefer WMI polling over the SolarWinds agent. Oct 18, 2022 · WMI requirements for SolarWinds accounts Tips for creating a non-administrator user for SAM application monitor polling to aid in troubleshooting by SolarWinds Support Aug 10, 2016 · I'm converting our systems that are currently monitored via WMI polling to using the Solarwinds Windows Agent. Ensure it is configured properly on target nodes or consider disabling WinRM on them. Note: Due to specific characteristics of WMI polling requests, polling a single WMI enabled object uses approximately five times the resources required to poll the same or similar object with SNMP on the same polling frequency. Review required operating systems, protocols, and third-party software. 2 as a single product installed on SolarWinds Platform 2023. Jun 6, 2022 · I've always used WMI when adding nodes. In some cases, ports are configurable. The typical result retrieves the performance data calculated by WMI providers such as the Windows OS or Microsoft Exchange Server. Administrator rights to SQL servers are needed for configuration, but are not required for polling if you use the optional SolarWinds Platform Agent for Windows. Old polling engine is successful at polling, but the new polling engine is not. Make sure your gMSA account is a member of the local Administrators group, both on the SolarWinds Platform polling engine and on the polled node. 2 feature: WinRM application polling Learn about using WinRM as the default transport method for WMI-based component monitors in SAM. You can create a new group or use an existing built-in group. For example, some WMI component monitors need to run as a specific user to This article describes the difference between the Preferred Polling Method options in the Advanced section of the Edit Application Monitor page when configuring application monitor templates and application monitors in SolarWinds SAM. Oct 1, 2015 · Im adding windows servers using WMI. SolarWinds does not provide support in connection with setting up a WMI. So far, the agent is working great for the remote sites, but are there any performance gains for running the agent locally to collect information versus having WMI polling on a node straight from the Orion server? Requirements You can use gMSA accounts only for polling via WinRM with Kerberos authentication. We ended up switching from WMI to the Solarwinds Agent about five years ago for both Windows Servers and Linux Servers. SolarWinds UDT license levels are provided as a reference. wmi requirements WMI Polling accounts dstip 15 Nov 2024 View Status History View Status History More Cancel The target node is configured for WMI polling. This topic introduces your options for monitoring hardware health for your SolarWinds Platform products, provides requirements and lists monitored hardware sensors. Aug 12, 2015 · This document provides a comprehensive list of port requirements for various SolarWinds products. WMI permissions to check if you receive a 'Test Failed' on the Edit Properties. SolarWinds Platform Agent resource consumption Agent resource consumption is variable and depends on what information is collected and how often the information is collected. If WinRM is disabled, WMI uses DCOM/RPC communication to allocate ports within the standard dynamic port range, 1025 — 65536. SolarWinds Platform agents that collect hardware health data were deployed. Also, the requirements for the agent as you mention including, updating Apr 1, 2015 · Currently polling a lot of internal servers using WMI and a couple of remote servers using the agent. This issue may be experienced with SolarWinds Agents when a job engine worker gets a spike in CPU utilization. If security is of a concern you might also consider using SNMP for all of your polling. does not consume much resource on the server side? Because I'm currently cutting over to not using Solarwinds agent anymore due to the remote agent restart requirement after upgrading Orion Platform, but using… Jun 10, 2025 · Server port requirements SolarWinds does not recommend the use of HTTP (Port 80). Some component monitors can use SolarWinds Platform agents to collect data. The WMI Monitor harnesses information from WMI providers already built into Windows-based devices via WinRM polling for faster, more secure communication. The service account I created in AD on the domain was placed in the built-in Administrators group. Agents An agent is software that provides a communication channel between the Orion server and a Windows or Linux/Unix computer. You can use the Credentials Library to manage credentials for component monitors that retrieve data from servers and services for SAM application monitors. Refer to Polling methods used by Orion. For WMI nodes, credentials specified during node registration to the SolarWinds Platform server are used for polling. Feature availability based on monitoring methods — with agents or agentless using SNMP or WMI The following table displays a comparison of which features are available for the Windows agent versus agentless. Asset Inventory uses VBScript to gather data about Windows updates on monitored nodes, which may cause false-positive alerts in antivirus scans. below is the partial results I get from the tool: WMI: usually enabled on Windows devices by default. The Web Help Desk Discovery Engine (WMI) allows you to discover Microsoft Windows-based assets based on the subnet or IP range. In this article, we will delve into the world of SolarWinds ports, exploring the essential ports required for its core components Using other polling methods (SolarWinds Platform Agent, WMI, or SNMPv3) with authentication or more complex element types (applications, firewalls, load balancers, or wireless controllers) will increase hardware requirements for the server. Adding nodes to the SolarWinds Platform with WinRM or WMI polling methods fail. This topic provides system requirements for SolarWinds Observability SaaS, including software, hardware, port, database, and cloud requirements. As a network administrator, ensuring the smooth operation of your monitoring tools is crucial for maintaining optimal network performance. To poll your environment, you can deploy agents that provide a communication channel between the SolarWinds Platform server and a computer you want to monitor. Help and Support To add WMI credentials, specify the Display Name, Username, and Password and click Save. Nov 15, 2016 · Hi Phillip, Here are some links that you might find helpful: Enable an alert monitoring on a polling engine - SolarWinds Worldwide, LLC. Nov 27, 2017 · Hi All, Am new to Solarwinds SAM. It mentions that ports 1024-65535 need to be open. Refer to product documentation for specific port information. This topic provides miminum requirements for small, medium, large, and extra-large deployments with multiple SolarWinds Platform products. Learn more about SolarWinds Platform products. 1 or later. Got stuck with one point which is related to the WMI port requirements- In the PDF it says: Monitors and templates using WMI These lists provide the component monitors… WMI or agent polling causes high CPU utilization on monitored Windows nodes in Orion When polling a node via WMI, the WMI process on the target machine experiences high CPU utilization. To reorder credentials within the polling method, go to the polling method tab (SNMP or WMI) and use the arrows in the Actions column. Select a polling method for polling data on monitored devices: external node (no status), SNMP, ICMP, WMI, agent. When planning an SolarWinds UDT installation, there are four main factors to keep in mind with respect to polling capacity: CPU, memory, number of polling engines, and polling engine settings. This topic describes how you can change the method for polling a device monitored with your SolarWinds Platform products. WMI is enabled on the remote server. fSecurity Event Manager (SEM) For a list of ports required to communicate with SolarWinds products, see Port requirements for all SolarWinds products. Help and Support SNMP and WMI polling comparison - SolarWinds Worldwide, LLC. SNMP access must be allowed to all SolarWinds polling engines. below is the partial results I get from the tool: NB: if you can check that UAC is disabled from 1 and enabled in server 2. Requirements You can use gMSA accounts only for polling via WinRM with Kerberos authentication. Customers rely on SolarWinds to drive operational resilience, from unified observability to enterprise-wide service management, through a simple, powerful, and secure portfolio built for hybrid IT. I’m trying to determine what permissions the non-admin account needs for it to use WMI polling on all servers and WMI requirements required by systems running Microsoft® Windows® operating systems to establish a successful WMI connection with a remote system. Prepare a SolarWinds NPM installation SolarWinds Network Performance Monitor requirements NPM software requirements Server port requirements NPM hardware requirements Apr 18, 2023 · Important: These recommended system requirements are for SolarWinds Server & Application Monitor (SAM) 2023. This topic describes requirements forNetPath - probe computer requirements, port requirements, system requirements, database storage requirements, cloud requirements, and scalability information. Port # Protocol Service/Process Direction Description 22 TCP SSH Bidirectional SSH traffic to the SolarWinds SEM VM. To learn about best practices for configuring your Web Help Desk installation securely, see Best practices to secure What authority on each Windows server does the WMI credentials need to perform the necessary polling? So far in my testing if I don't make the user an admin then I can't open the Serivce Control Manager. Obviously with all the fun breach issues of Solarwinds its not ideal for our polling accounts to be running with full domain admin privileges like Solarwinds wants. Learn more about multi-module system guidelines. As far as I know the SolarWinds agent is running with system privileges, with no way of modifying the permissions it's running with. As per your above response, I was under the assumption the basic requirements were: TCP Port 17777/17778 (both directions) - SolarWinds Information Service and API Jun 23, 2025 · What are the benefits when configuring the WinRM filtering as opposed to the existing WMI polling that is already working without making major changes in the AD Domain [Installation and configuration for Windows Remote Management - Win32 apps | Microsoft Learn] ? Troubleshoot issues you may encounter when using WinRM as the fetching method for WMI-based polling for SAM application monitor templates, application monitors, and component monitors. 4. If your use of Web Help Desk does not need to be public or internet-facing, install it on a server that is neither public, nor internet-facing. Resolution NPM implemented WMI polling method does not support polling of interfaces and in such case you will have to use SNMP as a node polling method to obtain interfaces' data. WMI requirements for SolarWinds accounts WMI account permissions required for WMI type polling method used in Orion. ) Provide details on how to configure such an account on the Windows device-side. This information includes: Host name Model Serial number Operating system Hard Dec 19, 2018 · Requirements to set up your credentials for accessing an AD domain controller outside the local UDT server domain. Although we use a domain So for WMI polling, the original article in that link is now revoked according to the solarwinds support rep I have a ticket opened with. For more information about enabling account privileges in WMI, see Configuring Distributed Component Object Model and User Account Oct 5, 2015 · I'm guessing that what you are looking for is in this article - SolarWinds Knowledge Base :: How to create a non-administrator user for SAM polling. Have been going through all the PDFs and also the videos for the better understanding of the Tool and its implementation. SolarWinds, a leading network monitoring platform, relies on various ports to communicate with devices and collect data. Using SNMPv3 would remove the need for a domain admin account to poll your servers while still requiring a level of authentication. An Orion Remote Collector is a mini polling engine that allows you to poll devices in your environment through WMI and SNMP. For Linux nodes, see Credentials and privileges used on Linux/Unix-based computers. With WMI you're in full control over which permissions a polling engine is having to your devices via the account being used. Learn about node-based and component-based licensing models for SolarWinds SAM. I am new to WMI, I understand there needs to be a certain level of access to the Windows server for Orion to poll WMI. Windows Remote Management (WinRM) is a protocol and set of services that enable remote management of Windows systems. SolarWinds strongly recommends that you install the SolarWinds Platform on a server that is neither public, nor internet-facing. Polled data is further processed and stored in the SolarWinds Orion database. This document provides a comprehensive list of port requirements for all SolarWinds products and features. Additionally, verify if your server has enough resources, especially for CPU. If the polling engine and device are separated by a firewall, SolarWinds recommends that you deploy an optional agent to securely monitor Windows servers and applications by WMI. With over 1200 SAM templates, many plugins, applications, and systems used in your environment—including Linux, Apache, AIX, Bind, Cisco, JMX, and more—are covered and presented in WMI Monitors are component monitors that use WMI communication to obtain the result of a WMI Query Language (WQL) query. Learn how to use Orion Remote Collectors (ORCs) with SAM. Jun 29, 2025 · Hi, we updated requirements on this page: Use gMSA accounts for Windows polling gMSA account needs to be member of LOCAL Administrators group on both sides (SolarWinds Platform polling engine and as well polled node). Some component monitors need to run in the context of a user account, while other component monitors need credentials to access information on target servers. We have found lots of articles explaining how that can be narrowed down to just one port needed for the actual WMI polling so that helps. Comprehensive port requirements for SolarWinds products like DameWare, DPA, ipMonitor, FSM, and more. I have found this page -… Feb 13, 2008 · I just downloaded the new App Monitor Module. WinRM is the default transport method used to fetch data for WMI-based component monitors. He gave me a link to this thwack post that may help Feb 13, 2023 · I am in the process of building out a new Orion 2022. Please use HTTPS (Port 443) to ensure that any web-related connections are secure. 1. Now, for auditing purposes, I'm instructed to remove that service account from the admin group and install the agent so that it can use the local account for monitoring. Our Windows team is very protective of their servers and who they give access to and how… Hyper-V cluster polling For cluster polling, the WMI user needs to be part of a domain group that exists on all clusters and has full cluster rights . The main reason is for WMI polling. ol4wo6djm w1bn3h 3yv0o roezro 1je2ctjo fwiaf fbxads 61tvo t0wq uljm